Chapter 5 · Mississippi Waterworks Operators Manual

Ground Water & Wells

Where Mississippi's water comes from, how aquifers work, and how a well is built, developed, and maintained.

Greg's take on this chapter

About 88% of Mississippi's public water systems run on ground water, so this chapter matters no matter what class you're studying for. Get confined vs. unconfined (water-table) aquifers straight, know your well-development vocabulary, and remember the disinfection numbers for a newly completed well โ€” they show up on every class exam.

1 Mississippi's ground water

About 88 percent of the water used by Mississippi public water systems is ground water, and every public water system in the state uses at least some ground water as a primary or backup source. Mississippi has 15 principal freshwater aquifers. Water percolates down from rainfall, dissolving minerals along the way โ€” mineral content increases with travel time until it reaches equilibrium, which is why chemistry can vary even within the same aquifer.

2 Aquifer types

The zone of saturation โ€” where all the spaces between soil particles are filled with water โ€” is the free ground-water reservoir, also called a water table aquifer or unconfined aquifer. A well completed here is a water table well; it's vulnerable to pollution from surface discharges and to water-table fluctuation.

A confined aquifer has an impervious formation above and below it, so the water is under pressure โ€” like water in a distribution main. If water rises above the top of the aquifer when a well taps it, that's an artesian aquifer; if it rises all the way to the top of the casing and overflows, that's a flowing artesian well.

3 Measuring aquifers and wells

  • Transmissivity โ€” the rate water flows through a vertical section of aquifer, expressed as ftยฒ/day. Mississippi aquifers range from about 5 to over 84,000 ftยฒ/day.
  • Permeability โ€” how easily water moves through the aquifer material, in gallons per day per square foot.
  • Porosity โ€” the percent of the formation's volume that's open space. High porosity doesn't guarantee high yield โ€” clay can have plenty of pore space but yield almost nothing because the openings are too small.
  • Drawdown โ€” the drop from static water level to pumping water level after stabilizing.
  • Specific capacity โ€” gallons per minute the well produces per foot of drawdown. Divide pumping rate (gpm) by drawdown (ft) to calculate it.

Mississippi ground water generally runs under 100 mg/l dissolved solids near an aquifer's outcrop area, and mineral content rises with depth โ€” over 1,000 mg/l is usually considered the freshwater downdip limit. Temperature rises about 1ยฐF for every 100 feet of depth.

4 Well construction

Most community supplies use drilled wells (2 to 48 inches in diameter), built with either the cable-tool percussion method (best for hard rock) or hydraulic rotary methods (best in unconsolidated soils). A casing lines the bore hole to stop it from caving and to keep the aquifer from being contaminated from the surface or other aquifers. Grouting fills the space between the casing and the bore-hole wall โ€” usually a high-early-strength or neat cement โ€” to seal out contamination and protect against corrosion.

Well screens collect water while holding back formation material; screen selection comes from a sieve analysis of the aquifer's sand. Corrosion, not casing failure, is the more common cause of screen failure. Well development โ€” over-pumping, surging, or jetting โ€” removes fine sand, silt, and drilling mud around the screen so the well can produce at full capacity.

5 Disinfecting a completed well

After construction, pump the well until the water runs clear with no fine sand, then disinfect the well and adjacent aquifer using a 50 mg/l free chlorine solution held for 24 hours. Afterward, pump until two consecutive chlorine-free samples, collected at least two hours of continuous pumping apart, both show no coliform bacteria before the well goes into service.

6 Measuring water levels and tracking well performance

Many wells have an airline: a small tube of known length that runs down beside the pump, below the water level. Pump air into it until the gauge stops rising; that pressure equals the depth of water over the bottom of the tube. Then:

Depth to water = airline length โˆ’ (gauge psi ร— 2.31)

Example. A 250-foot airline reads 60 psi. Water over the tube: 60 ร— 2.31 = 138.6 ft. Depth to water: 250 โˆ’ 138.6 = 111.4 feet. Read it with the pump off for the static level, and after the pump has run a while for the pumping level. The difference is the drawdown.

Check specific capacity (gpm รท drawdown) on a regular schedule and compare it with the original test. A steady decline means the screen, or the formation around it, is clogging. Many operators plan rehabilitation when specific capacity falls about 25% below the original, because plugging gets harder to remove the longer it's left.

7 Protecting the wellhead

Most well contamination gets in at the top, not through the aquifer. Good wellhead practice:

  • The casing extends above grade and above the floor of any pump house, and the ground slopes away so water drains off.
  • A sanitary seal or well cap keeps out insects, rodents, and surface water, and the casing vent is turned down and screened.
  • A concrete pad around the casing sheds rain and protects the grout seal.
  • No pits, and nothing stored nearby that could leak: fuel, pesticides, fertilizer, or chemicals.
  • Sewers, septic systems, and animal pens stay outside the protective distances MSDH requires, and the site is fenced and locked.
  • Abandoned wells are sealed with grout from the bottom up. An open or poorly plugged old well is a straight path from the surface into the aquifer.

A community wellhead protection program goes further: it maps the land that recharges the well, inventories possible sources of contamination, and works with local officials to manage land use there.

8 Troubleshooting and rehabilitating wells

SymptomLikely causeWhat to do
Falling yield and specific capacityScreen encrusted with iron, manganese, or calcium scale, or iron bacteriaRehabilitate: acid or chlorine treatment with surging or brushing, then redevelop
Sand in the waterDamaged or corroded screen, wrong slot size, or pumping too hardLower the pumping rate, inspect with a downhole camera, and repair or replace the screen
Red water, slime, or odorIron bacteria or sulfate-reducing bacteriaShock chlorinate, clean the well, and keep up routine disinfection
Coliform in the raw waterSurface water entering at the wellhead, or a casing or grout failureInspect the wellhead, fix the defect, disinfect, and resample before use
Pump runs but delivers little waterWater drawn down below the pump intake, or a worn pumpCheck water levels, pump amps, and discharge pressure

After any work that opens the well, disinfect it and get satisfactory bacteriological results before putting it back in service.

Go deeper: Mississippi's AquifersDrill a virtual well anywhere in the state, compare all 16 major aquifers, and see how the Delta's water levels have changed.

๐Ÿ“Œ Numbers Greg wants you to memorize

  • 88% of Mississippi public water systems use ground water.
  • 15 principal freshwater aquifers in Mississippi.
  • Specific capacity = pumping rate (gpm) รท drawdown (ft).
  • New-well disinfection: 50 mg/l free chlorine held 24 hours, then two clean coliform samples.
  • Ground water temperature rises about 1ยฐF per 100 ft of depth.
  • Over 1,000 mg/l dissolved solids is usually the freshwater downdip limit.
  • Depth to water = airline length โˆ’ (psi ร— 2.31).
  • Plan rehabilitation when specific capacity drops about 25% below the original test.
  • Ground Water Rule: raw-water sample from each well within 24 hours of a coliform-positive routine sample.
Key terms

Words to know for Chapter 5

Plain-language definitions from the LearnWater glossary.

Open the full glossary โ†’

Check yourself

Quick check: 5 questions

Random questions from this chapter's bank. Your answers count toward your progress in the Learning Center.

Flash cards

Tap a card to flip it

Study these in the flash card trainer โ†’

Ask Greg

Questions about Chapter 5?

Greg answers from the operators manual and works formulas right in your browser. Ask him to search EPA, NRWA, or MsRWA and only your search words go to that site.

Finished this chapter?Mark it complete to update your progress.